The boiler produces 8 kg/s of steam at 40 bar and 500 oC. This is expanded to 2 bar with an isentropic efficiency of 0.88. The pump is supplied with feed water at 0.5 bar and 30 oC and delivers it to the boiler at 31 oC and 40 bar. Calculate the net power output
Read MoreEnthalpy of steam at 180 bar, 550 0C – 3420 kJ/kg Exhaust steam enthalpy at isentropic expansion from 180 bar to 2 bar – 2430 kJ/kg Enthalpy of boiler feed water – 504.7 kJ/kg Efficiency of boiler - 80 % Calorific value of coal – 4500 kcal/kg Steam flow rate
Read MoreProject in Brief The proposed ethanol plant of 50 KLPD capacities will employ fermentation, multi pressure distillation system, & composting. Nearby Sugar mill will supply molasses, while the boiler will provide the steam and power will be purchased from the grid for the proposed ethanol plant.
Read More15/4/2020 · Analyzed boiler with marked stream flows of fuel, air, ash, water, flue gas, and steam passed the boundary of control area: 1 – fuel, 2 – slag, 3 – ambient air, 4 – flue gas, 5 – feedwater, 6 – steam to reheat (from High-Pressure turbine), 7 – injection water tot FG1
Read MoreFounded in 1929, Cleaver-Brooks is a complete boiler room solutions provider that helps businesses run better every day. It develops hot water and steam generation products aimed at integrating and optimizing the total boiler, burner, controls, and stack exhaust system to maximize energy efficiency and reliability while minimizing emissions.
Read Morec. Use price of fuel burned in the boiler for CS,f; ms is total auxiliary boiler steam capacity (kg/s). d. q is total water capacity (m3/s). e. Qc is total auxiliary cooling capacity (kJ/s), T is absolute temperature (K). f. QH is total auxiliary heating capacity (kJ/s), T is
Read MoreThe boiler p roduces 8 kg/s of steam at 40 bar and 500 oC. This is expanded to 2 bar with an isentr opic efficiency of 0.88. h2= m c + pv = 1 x 4186 x 31 + 40 x 10 5 x 0.001 =133.7 kJ/kg The power input to the pum p is 8(133.7 125.7) = 64 kW Net Power
Read MoreFounded in 1929, Cleaver-Brooks is a complete boiler room solutions provider that helps businesses run better every day. It develops hot water and steam generation products aimed at integrating and optimizing the total boiler, burner, controls, and stack exhaust system to maximize energy efficiency and reliability while minimizing emissions.
Read Morec. Use price of fuel burned in the boiler for CS,f; ms is total auxiliary boiler steam capacity (kg/s). d. q is total water capacity (m3/s). e. Qc is total auxiliary cooling capacity (kJ/s), T is absolute temperature (K). f. QH is total auxiliary heating capacity (kJ/s), T is
Read MoreThe boiler p roduces 8 kg/s of steam at 40 bar and 500 oC. This is expanded to 2 bar with an isentr opic efficiency of 0.88. h2= m c + pv = 1 x 4186 x 31 + 40 x 10 5 x 0.001 =133.7 kJ/kg The power input to the pum p is 8(133.7 125.7) = 64 kW Net Power
Read MoreThe resulting volume of flash steam from the 18.6 kg of boiler water is: (18.6 kg x 16%) x 1.673 m3/kg = 4.98 m3. For comparison, the volume of water, is reduced to: (18.6 kg x 84%) x 0.001 m3/kg = 0.015 6 m3. The very high energy flowrate, and huge change in volume between the upstream and downstream sides of the blowdown valve, mean that
Read More17/9/2017 · Thermodynamic assignment 2. 1. Thermodynamics Assignment 02 Name: Dilshan K.M.G.L. Index Number: 150131A. 2. Question 1 A steam power plant operates between a boiler pressure of 40 bar and a condenser pressure of 0.04 bar. Calculate the cycle efficiency, work ratio and specific stream consumption for I. Carnot cycle P1 = P2 = 40 bar = 4000 kPa
Read More